Three-C Electrical Company, Inc.

subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link
Engineering | Construction | Specialty Services
PWRM | InfraRed | RPM | All Services
About Us | Contact Info | Directions | Careers
subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

Engineering

Engineering Services

Engineering Services Group:   Handles all phases of substation construction, installation and repair, High Voltage Cable Installation, Splicing and Termination, Fault Location, Underground System Layout and Maintenance, and Cogeneration. Three-C is ready to assist you with all stages of power systems construction - from site excavation to start-up, from new construction to retrofit work.

Provides all services from startups, system evaluations, short circuit coordination studies, and harmonics measurement to complete acceptance and preventive maintenance testing on all types of power equipment, including Transformers, Circuit Breakers, Rotating Equipment, Relays, Battery Systems, and Dielectric Fluids.

 

 

List of Engineering Services Provided
Circuit Breakers:
Low Voltage

Primary Current Injection
Secondary Injection
Contact Resistance
Insulation Resistance
Functional
Solid State Trip Unit Retrofits


Circuit Breakers:
Medium & High Voltage
Contact Resistance (up to 100A)
Time/Motion Analysis
Oil/SF
6 Testing
Leak Testing & Repair
Functional
Vacuum Bottle Integrity
Internal Inspections


Transformers
Oil ASTM Screen Tests
Dissolved Gas In Oil Analysis
PCB Analysis
Turns Ratio
Dielectric Absorption/PI Index
Insulation Power Factor
Transformer/Bushings
Oil/Excitation
Load Tap Changer Service
Leak Testing & Repair
Oil Reclamation
Mechanical Services
Vibrational Analysis
Non Destructive Examination


Protective Relays
Functional Testing
Operational Testing
Calibration


Switches: Low, Medium &
High Voltage

Contact Resistance (up to 100A)
Insulation Resistance
Functional
Mechanical


Instrumentation
Electrical-KWH, A, V, pF, Hz,
SS, KW, KVAr, KVA
Process Control: Pressure, RPM,
Temperature, Flow, 4-20mA
RTDs
Calibration
Functional
Rescaling
Instrument Transformers
CT, VT, PT, CCVT
Ratio & Polarity
Insulation Resistance
Burden/Saturation
Insulation Power Factor
Functional


Cable Testing: 
Low, Medium & High Voltage
Hipot
Insulation Power Factor
Dielectric Absorption
Insulation Resistance
Shield Continuity
Cable Locating
Fault Locating


Rotating Equipment:
Synchronous/Induction
Generators & Motors

Insulation Power Factor
Dielectric Absorption
Polarization Index
Load Testing
Field Resistance
Voltage Regulator Calibration
Vibrational Analysis
Shaft Discharge Analysis
Magnetization Analysis
Degaussing

Switchgear
Thermoscan
Functional
Insulation Resistance

Ground Systems
Earth Resistivity Studies
Grid Resistance Measurements
GFI Calibration


Battery Systems
AC Impedance Measurements
System Ripple Measurements
DC Voltage Measurements
Specific Gravity
Load Testing
Charger Calibration


Engineering Services
System Studies
Short Circuit Studies
Coordination Studies
Load Flow/Voltage Drop
Power Quality
Harmonics Measurement
Voltage Disturbance Analysis
Power Metering
CAD/SCADA
Multiyear PM Programs
System Start Up
Troubleshooting
Design Services

About Us | Contact Us | ©2007 Three-C Electrical Company, Inc.